Four Fan

1.Functions:
1. Fan Assisted Airflow to Eliminate Hot Spots
In almost any data center today there is at least one high density server rack that possesses a unique cooling to satisfy the load of these few racks often leads to over-cooling the other racks and significantly deteriorates the energy efficiency of the facility. Finding the balance to ensure in over-cooling is the key to achieving reliability.
2.Effectively Manage Dense Server Racks & Blades
ABU-S-1 power fan is designed to provide a blast of cooling through an individual airflow panel. Multiple control options are available to automatically turn on when conditions require additional cooling.
Equipped with a variable speed fan drive, the fan can be throttled up or down based on the heat load requirements. This powerful solution is ideal for solving the toughest hot spots in data center.
Easy to install, power fan is ideal for retrofit into existing data centers or as part of a new advanced cooling strategy. Power fan is an excellent choice for cooling the most stubborn hot spots.



2.Product features
0-25kW supportable IT load per panel/fan combination
PID multiloop control system
No regularly-scheduled maintenance required
Various of models & configurations available 

3.Model selection
A.One rack mounted sensor and control networking four fan type
(product code: ABU-4AC200-SN)
a.The temperature sensor is thermocouple
b.Clients can set it from 0oC to 100oC
c.It's free to set the starting temperature and operating temperature from 0oC to 100oC
d.The fan uses AC stepless speed control
e.The fan speed is free to adjust from 0 to 100%
f.There are four fans
g.It has (RS485) communication interface


B.Multi-rack mounted sensor and control networking four fan type
(product code: ABU-4AC200-MN)
a.The temperature sensor is bus-based and high accuracy temperature measurement
b.The rack mounted sensor can maximumly  be 32pcs, usually is 3 to 5.
c.Clients can set it from 0oC to 100oC
d.It's free to set the starting temperature and operating temperature from 0oC to 100oC
e.The fan uses AC stepless speed control
f.The fan speed is free to adjust from 0 to 100%
g.There are four fans
h.It has (RS485) communication interface